Manufacturing Accuracy, Intaglio Surface Adaptation, and Survival of Additively and Subtractively Manufactured Definitive Resin Crowns After Cyclic Loading: An In Vitro Study

  • Molinero-Mourelle P
  • Limones A
  • Güven M
  • et al.
2Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

PURPOSE: To assess the manufacturing accuracy, intaglio surface adaptation, and survival of resin-based CAD/CAM definitive crowns created via additive manufacturing (AM) or subtractive manufacturing (SM). MATERIALS AND METHODS: A maxillary right first molar crown was digitally designed and manufactured using AM hybrid resin composite (VarseoSmile Crown Plus, Bego [AM-HRC]), AM glass filler-reinforced resin composite (Crowntec, Saremco Dental [AM-RC]), and SM polymer-infiltrated ceramic (Vita Enamic, VITA Zahnfabrik [SM-PICN]). Manufacturing accuracy (trueness and precision) was assessed by computing the root mean square (RMS) error (in μm; n = 15 per material). Intaglio surface adaptation was assessed by calculating the average gap distance (μm). Ten crowns from each group were cemented on fiberglass-reinforced epoxy resin dies and cyclically loaded to simulate 5 years of functional loading. One-way ANOVA, post hoc Bonferroni comparison tests, and Levene's test were used to analyze the data (α = .05). RESULTS: AM-RC had higher overall trueness than AM-HRC and SM-PICN (P ≤ .05), whereas the trueness of AM-RC on the external surface was similar to that of SM-PICN (P = .99) and higher than AM-HRC (P = .001). SM-PICN had lower precision than AM-RC and AM-HRC overall and at internal occlusal surfaces (P ≤ .05). Overall intaglio surface adaptation was similar between all groups (P = .531). However, for the axial intaglio surface, AM-RC and AM-HRC had higher adaptation than SM-PICN (P ≤ .05). All tested crowns survived the cyclic loading simulation of 5 years clinical use. CONCLUSIONS: AM-RC showed high manufacturing accuracy and adaptation. The tested resin-based CAD/CAM materials demonstrated clinically acceptable manufacturing accuracy and simulated medium-term durability, justifying the initiation of clinical investigations to determine their potential implementation in daily clinical practice.

Cite

CITATION STYLE

APA

Molinero-Mourelle, P., Limones, A., Güven, M. E., Fonseca, M., Peutzfeldt, A., Yilmaz, B., & Cakmak, G. (2024). Manufacturing Accuracy, Intaglio Surface Adaptation, and Survival of Additively and Subtractively Manufactured Definitive Resin Crowns After Cyclic Loading: An In Vitro Study. International Journal of Prosthodontics, 37(7), S175–S185. https://doi.org/10.11607/ijp.8976

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free