Validation of an algorithm for continuous monitoring of atrial fibrillation using a consumer smartwatch

76Citations
Citations of this article
111Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Consumer devices with broad reach may be useful in screening for atrial fibrillation (AF) in appropriate populations. However, currently no consumer devices are capable of continuous monitoring for AF. Objective: The purpose of this study was to estimate the sensitivity and specificity of a smartwatch algorithm for continuous detection of AF from sinus rhythm in a free-living setting. Methods: We studied a commercially available smartwatch with photoplethysmography (W-PPG) and electrocardiogram (W-ECG) capabilities. We validated a novel W-PPG algorithm combined with a W-ECG algorithm in a free-living setting, and compared the results to those of a 28-day continuous ECG patch (P-ECG). Results: A total of 204 participants completed the free-living study, recording 81,944 hours with both P-ECG and smartwatch measurements. We found sensitivity of 87.8% (95% confidence interval [CI] 83.6%–91.0%) and specificity of 97.4% (95% CI 97.1%–97.7%) for the W-PPG algorithm (every 5-minute classification); sensitivity of 98.9% (95% CI 98.1%–99.4%) and specificity of 99.3% (95% CI 99.1%–99.5%) for the W-ECG algorithm; and sensitivity of 96.9% (95% CI 93.7%–98.5%) and specificity of 99.3% (95% CI 98.4%–99.7%) for W-PPG triggered W-ECG with a single W-ECG required for confirmation of AF. We found a very strong correlation of W-PPG in quantifying AF burden compared to P-ECG (r = 0.98). Conclusion: Our findings demonstrate that a novel algorithm using a commercially available smartwatch can continuously detect AF with excellent performance and that confirmation with W-ECG further enhances specificity. In addition, our W-PPG algorithm can estimate AF burden. Further research is needed to determine whether this algorithm is useful in screening for AF in select at-risk patients.

Cite

CITATION STYLE

APA

Avram, R., Ramsis, M., Cristal, A. D., Nathan, V., Zhu, L., Kim, J., … Olgin, J. E. (2021). Validation of an algorithm for continuous monitoring of atrial fibrillation using a consumer smartwatch. Heart Rhythm, 18(9), 1482–1490. https://doi.org/10.1016/j.hrthm.2021.03.044

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free