Validation of the Colibrí Instrument for Automated Preparation of MALDI-TOF MS Targets for Yeast Identification

13Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Recently, Copan (Italy) introduced the Colibrí instrument for automated colony picking and preparation of matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) target plates. Our study aimed to validate this system for yeasts as such testing has not been performed yet and is a missing link needed to implement the system for routine use. Fifty-five Candida strains were selected to evaluate the accuracy of Colibrí. For each strain, a sheep blood agar plate supplemented with X and V factors (HEM) and a Sabouraud agar plate (SAB) were inoculated and incubated using the WASPlab specimen processing system (Copan). After 18 h and 36 h of incubation, the isolates were spotted in parallel using Colibrí and manually onto MALDI-TOF target plates with the addition of formic acid and identified using MALDI-TOF mass spectrometry. The reproducibility was evaluated using ATCC reference and clinical isolate-derived strains. The cumulative percentage of acceptable identification scores (IDs) after 36 h was 91% for strains cultured on HEM plates using both Colibrí and the manual method. The SAB plates showed inferior results for both Colibrí (76%) and the manual method (78%). We observed an overall agreement of 92% at 18 h for identification of the strains on the HEM plates between Colibrí and the manual method and 94% after 36 h. For the SAB plates, the agreement was 78% after 18 h and 84% after 36 h. Apart from Candida dubliniensis and Candida tropicalis, all Candida species were identified with 100% accuracy using Colibrí on HEM plates. We observed good agreement between Colibrí and the manual reference method. These results demonstrate that Colibrí is a reliable system for MALDI-TOF target preparation for yeast identification, allowing increased standardization and less hands-on time.

Cite

CITATION STYLE

APA

Heestermans, R., Herroelen, P., Emmerechts, K., Vandoorslaer, K., De Geyter, D., Demuyser, T., … Muyldermans, A. (2022). Validation of the Colibrí Instrument for Automated Preparation of MALDI-TOF MS Targets for Yeast Identification. Journal of Clinical Microbiology, 60(7). https://doi.org/10.1128/jcm.00237-22

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free