Full scale wind turbine test of vortex generators mounted on the entire blade

16Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Measurements on a heavily instrumented pitch regulated variable speed Vestas V52 850 kW wind turbine situated at the DTU Risø Campus are carried out, where the effect of vortex generators mounted on almost the entire blade is tested with and without leading edge roughness. The measurements are compared to the predictions carried out by a developed design tool, where the effect of vortex generators and leading edge roughness is simulated using engineering models. The measurements showed that if vortex generators are mounted there is an increase in flapwise blade moments if the blades are clean, but also that the loads are almost neutral when vortex generators are installed if there is leading edge roughness on the blades. Finally, it was shown that there was a good agreement between the measurements and the predictions from the design tool.

Cite

CITATION STYLE

APA

Bak, C., Skrzypiński, W., Gaunaa, M., Villanueva, H., Brønnum, N. F., & Kruse, E. K. (2016). Full scale wind turbine test of vortex generators mounted on the entire blade. In Journal of Physics: Conference Series (Vol. 753). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/753/2/022001