9-Month Clinical, Angiographic, and Intravascular Ultrasound Results of a Prospective Evaluation of the Axxess Self-Expanding Biolimus A9-Eluting Stent in Coronary Bifurcation Lesions. The DIVERGE (Drug-Eluting Stent Intervention for Treating Side Branches Effectively) Study

102Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: This study sought to assess the safety and performance of the Axxess (Devax Inc., Lake Forest, California) self-expanding drug-eluting stent in coronary bifurcation lesions. Background: Percutaneous treatment of coronary bifurcations is a predictor of adverse late outcomes, in part because of the lack of dedicated devices. Methods: Patients with de novo bifurcation lesions were prospectively enrolled in a multicenter study. The Axxess stent was deployed at the level of the carina followed by additional sirolimus-eluting stents in the distal parent vessel (PV) and/or side branch (SB). All patients underwent clinical follow-up at 9 months; 150 were to receive control angiography and 76 were to receive intravascular ultrasound. The primary end point was the rate of major adverse cardiac events (MACE): a composite of death, myocardial infarction (MI), and target lesion revascularization (TLR). Secondary end points included in-segment restenosis, late loss, and percent neointimal volume obstruction. Results: Overall, 302 patients were treated with 299 Axxess stents (99%). Additional stenting of 1 branch was performed in 21.7% of patients (17.7% PV, 4% SB), and of both branches in 64.7%. At 9 months, 99.3% of patients returned for clinical follow-up; from the angiographic and IVUS substudies, 93.3% and 89.4% returned. The cumulative 9-month MACE rate was 7.7% (0.7% death, 3.3% non-Q-wave MI, 1.0% Q-wave MI, 4.3% TLR). Subacute and late stent thrombosis occurred in 0.7% and 0.3% of patients. Total restenosis was 6.4% (3.6% PV, 4.3% SB), late loss was 0.20 ± 0.41 mm in the PV and 0.17 ± 0.34 mm in the SB. In the Axxess stent segment, percent neointimal volume obstruction was 4.3 ± 5.2%. Conclusions: This prospective multicenter study confirms the safety and performance of the Axxess stent in bifurcation lesions. (Drug-Eluting Stent Intervention for Treating Side Branches Effectively; ACTRN12606000259549). © 2009 American College of Cardiology Foundation.

Cite

CITATION STYLE

APA

Verheye, S., Agostoni, P., Dubois, C. L., Dens, J., Ormiston, J., Worthley, S., … Lansky, A. J. (2009). 9-Month Clinical, Angiographic, and Intravascular Ultrasound Results of a Prospective Evaluation of the Axxess Self-Expanding Biolimus A9-Eluting Stent in Coronary Bifurcation Lesions. The DIVERGE (Drug-Eluting Stent Intervention for Treating Side Branches Effectively) Study. Journal of the American College of Cardiology, 53(12), 1031–1039. https://doi.org/10.1016/j.jacc.2008.12.012

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free