A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection

  • Imagawa A
  • Hata H
  • Nakatsu M
  • et al.
N/ACitations
Citations of this article
21Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

BACKGROUND AND STUDY AIMS: Propofol administration via a target-controlled infusion system with bispectral index monitoring (BIS/TCI system) is expected to prevent complications from sedation during complex and long endoscopic procedures. We evaluated the feasibility of setting the BIS/TCI system for non-anesthesiologist administration of propofol (NAAP) during endoscopic submucosal dissection (ESD).PATIENTS AND METHODS: From May 2009 to February 2013, 250 patients with esophagogastric neoplasms were treated with ESD using the BIS/TCI system with NAAP. In the TCI system, the initial target blood concentration of propofol was set at 1.2 μg/mL. The titration speed of propofol was adjusted according to the BIS score and the movement of the patient. The BIS target level ranged from moderate to deep sedation, at which a stable BIS score between 60 and 80 was obtained.RESULTS: In 80.4 % of patients, it was possible to maintain stable sedation with a blood concentration of propofol of less than 1.6 µg/mL using TCI throughout the ESD procedure. The default setting for ideal blood concentration of propofol was 1.2 μg/mL, because the medians of the lower and upper bounds of blood concentration were 1.2 μg/mL (range 0.6 - 1.8 μg/mL) and 1.4 μg/mL (range 1.0 - 3.8 μg/mL), respectively. Although hypotension occurred in 27 patients (10.8 %), oxygen desaturation occurred in only nine patients (3.6 %), and severe desaturation in only two patients (0.8 %).CONCLUSIONS: Using our settings, it is possible for a non-anesthesiologist to maintain stable sedation during a lengthy endoscopic procedure through propofol sedation with a BIS/TCI system.

Cite

CITATION STYLE

APA

Imagawa, A., Hata, H., Nakatsu, M., Matsumi, A., Ueta, E., Suto, K., … Ando, M. (2014). A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection. Endoscopy International Open, 03(01), E2–E6. https://doi.org/10.1055/s-0034-1377519

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free