Estudo experimental do implante transcateter de prótese valvada autoexpansível na via de saída do ventrículo direito em porcos

0Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Introduction: Patients with congenital heart disease who underwent pulmonary valvotomy or surgery to open the pulmonary valve ring are prone to develop residual pulmonary insufficiency or stenosis that may lead to right heart failure with clinical deterioration. These children require multiple interventions throughout their lives, which impose a high rate of morbidity and mortality. Objective: To develop a less invasive technique for implantation of a valved prosthesis through the right ventricle. Methods: The valved prosthesis consists of an auto expanding metal stent built with nitinol, surrounded with polyester, where the three leaflets of bovine pericardium were mounted. Twelve pigs were used to perform the implants. Echocardiographic control was performed immediately after implantation and one, four, eight and 12 weeks. Results: One animal showed reflux of moderate to severe and three mild reflux. Transvalvular gradients measured before implantation ranged from 3 to 6 mmHg and that soon after the implant was increased, ranging from 7 to 45 mmHg. There was a decrease in these gradients during follow up and in only four of the twelve animals the gradients were above 20 mmHg. Thrombus formation occurred in the prosthesis of six animals, and this was the most frequent complication. Conclusion: These findings highlight the need for studies with the use of anticoagulants and antiplatelet, an attempt to reduce this event. The study aims to contribute for the start of the use of prosthetic heart valves that could be implanted through minimally invasive techniques without the use of cardiopulmonary bypass. Descriptors: Pulmonary Valve Insufficiency. Pulmonary Surgical Procedures. Pulmonary Valve Stenosis.

Cite

CITATION STYLE

APA

Guilhen, J. C. S., Palma, J. H., Gaia, D. F., de Araujo, A. T. V., Teles, C. A., Branco, J. N., & Buffolo, E. (2011). Estudo experimental do implante transcateter de prótese valvada autoexpansível na via de saída do ventrículo direito em porcos. Brazilian Journal of Cardiovascular Surgery, 26(3), 348–354. https://doi.org/10.5935/1678-9741.20110008

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free