Abstract
Electrochemical atomic force microscopy (EC-AFM) enables measurement of electrode topography and mechanical properties during electrochemical reactions. However, for aqueous-based reactions that make gas products, such as CO 2 reduction and water splitting into CO/H 2 , current densities below 1 mA cm −2 have been necessary to prevent formation of bubbles at the electrode; such bubbles can stick to the AFM probe and prevent further AFM imaging. Here, we demonstrate a novel cell design with a gas-diffusion electrode (GDE) to exhaust the gas products, thereby enabling high current density EC-AFM measurements at 1, 10, and 100 mA cm −2 that are not disturbed by bubble formation at the electrode surface. These experiments revealed a stable morphological structure of Cu catalysts deposited on GDEs during high current density operation. Systematic spatially resolved maps of deformation and adhesion showed no signs of a gas-liquid interface between catalyst particles of the GDE.
Cite
CITATION STYLE
Nesbitt, N. T., & Smith, W. A. (2021). Operando Topography and Mechanical Property Mapping of CO 2 Reduction Gas-Diffusion Electrodes Operating at High Current Densities. Journal of The Electrochemical Society, 168(4), 044505. https://doi.org/10.1149/1945-7111/abf183