An intraorbital metallic foreign body

7Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A 30?year?old male presented with diplopia for 20 days post occupational accident involving left side of his nose, while he was working with a nail gun. He was fully conscious and did not have any neurological deficits. Patient narrated the mechanism of injury and was sure that the nail fell down after hitting the left side of his nose. He had normal vision, but extra ocular movements were restricted and painful. Computed tomography (CT) scan revealed a curved metal object lodged in the posterior aspect of the left orbit extending diagonally from medial wall to the anterior?superior aspect of the orbital roof. The object was removed via a small surgical approach, inflicting least possible surgical trauma. Post surgery, the patient recovered with complete resolution of diplopia. The original aspects of this case are the lack of signs of a foreign body entry and its relative harmlessness in spite of its large size.

Cite

CITATION STYLE

APA

Asif, J. A., Pohchi, A., Alam, M. K., Athar, Y., & Shiekh, R. A. (2014). An intraorbital metallic foreign body. Indian Journal of Ophthalmology, 62(11), 1098–1100. https://doi.org/10.4103/0301-4738.146756