Effect of transvenous cardiac resynchronization therapy device implantation on cardiac troponin I release

7Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Your institution provides access to this article.

Abstract

Background: Pacemaker and implantable cardioverter defibrillator (ICD) implantation increases cardiac troponin I (cTnI) levels which indicates myocardial injury. During implantation of a cardiac resynchronization therapy (CRT) device, balloon inflation for coronary sinus (CS) venogram, cannulation of CS side branch, and electrode advancement may interfere with CS drainage and, hence, may decrease the washout of toxic metabolites from the heart. Thus, CRT implantation may further increase cTnI levels. In this study, we investigated the effects of CRT implantation on cTnI release. Methods: We included 10 patients (mean age = 57 ± 15 years) in whom a successful transvenous CRT system was implanted (CRT group). Twenty patients (mean age = 65 ± 10 years) who underwent a transvenous pacemaker or ICD implantation were included as the control group. Blood samples for cTnI were drawn at baseline and at six, 12, 18, and 24 hours thereafter. Results: Baseline median cTnI levels were similar in CRT and control groups (0.03 ng/mL vs 0.02 ng/mL, respectively; P = 0.1). Postoperative cTnI levels during 24 hours were significantly higher in the CRT group (P < 0.05) by two-way repeated measures of analyis of variance. Post hoc analysis revealed that cTnI levels were higher at the 6th, 12th, 18th, and 24th hours compared to baseline levels (P < 0.001, P < 0.001, P < 0.01, and P < 0.01, respectively). There was a significant difference in the area under the curves (AUCs) of cTnI measurements (1.79 hr·ng/mL in the CRT group and 0.78 hr·ng/mL in the control group, P < 0.05). Conclusion: Postoperative cTnI levels were higher after CRT implantation than simple pacemaker/ICD implantation. This may be due to CS manipulation during CRT implantation. © 2007, The Authors.

Cite

CITATION STYLE

APA

Altin, T., Akyurek, O., Vurgun, K., Beton, O., Sayin, T., Kilickap, M., … Erol, C. (2007). Effect of transvenous cardiac resynchronization therapy device implantation on cardiac troponin I release. PACE - Pacing and Clinical Electrophysiology, 30(11), 1356–1362. https://doi.org/10.1111/j.1540-8159.2007.00871.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free