Pre-hospital rule-out of non-ST-segment elevation acute coronary syndrome by a single troponin: final one-year outcomes of the ARTICA randomised trial

8Citations
Citations of this article
38Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background and The healthcare burden of acute chest pain is enormous. In the randomized ARTICA trial, we showed that pre-hospital aims identification of low-risk patients and rule-out of non-ST-segment elevation acute coronary syndrome (NSTE-ACS) with point-of-care (POC) troponin measurement reduces 30-day healthcare costs with low major adverse cardiac events (MACE) incidence. Here we present the final 1-year results of the ARTICA trial. Methods Low-risk patients with suspected NSTE-ACS were randomized to pre-hospital rule-out with POC troponin measurement or emergency department (ED) transfer. Primary 1-year outcome was healthcare costs. Secondary outcomes were safety, quality of life (QoL), and cost-effectiveness. Safety was defined as a 1-year MACE consisting of ACS, unplanned revascularization, or all-cause death. QoL was measured with EuroQol-5D-5L questionnaires. Cost-effectiveness was defined as 1-year healthcare costs difference per QoL difference. Results Follow-up was completed for all 863 patients. Healthcare costs were significantly lower in the pre-hospital strategy (€1932 ± €2784 vs. €2649 ± €2750), mean difference €717 [95% confidence interval (CI) €347 to €1087; P < 0.001]. In the total population, the 1-year MACE rate was comparable between groups [5.1% (22/434) in the pre-hospital strategy vs. 4.2% (18/429) in the ED strategy; P = 0.54]. In the ruled-out ACS population, 1-year MACE remained low [1.7% (7/419) vs. 1.4% (6/417)], risk difference 0.2% (95% CI -1.4% to 1.9%; P = 0.79). QoL showed no significant difference between strategies. Conclusions Pre-hospital rule-out of NSTE-ACS with POC troponin testing in low-risk patients is cost-effective, as expressed by a sustainable healthcare cost reduction and no significant effect on QoL. One-year MACE remained low for both strategies.

Cite

CITATION STYLE

APA

Aarts, G. W. A., Camaro, C., Adang, E. M. M., Rodwell, L., van Hout, R., Brok, G., … van Royen, N. (2024). Pre-hospital rule-out of non-ST-segment elevation acute coronary syndrome by a single troponin: final one-year outcomes of the ARTICA randomised trial. European Heart Journal - Quality of Care and Clinical Outcomes, 10(5), 411–420. https://doi.org/10.1093/ehjqcco/qcae004

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free