Comparison of percutaneous microwave/radiofrequency ablation liver partition and portal vein embolization versus transarterial chemoembolization and portal vein embolization for planned hepatectomy with insufficient future liver remnant

6Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: In China, both percutaneous microwave/radiofrequency ablation liver partition plus portal vein embolization (PALPP) and transarterial chemoembolization (TACE) plus portal vein embolization (PVE) have been utilized in planned hepatectomy. However, there is a lack of comparative studies on the effectiveness of these two techniques for cases with insufficient future liver remnant (FLR). Methods: Patients were categorized into either the PALPP group or the TACE + PVE group. Clinical data, including FLR growth rate, complications, secondary resection rate, and overall survival rate, were compared and analyzed for both groups retrospectively. Results: Between December 2014 and October 2021, a total of 29 patients underwent TACE + PVE (n = 12) and PALPP (n = 17). In the TACE + PVE group, 7 patients successfully underwent two-stage hepatectomy, while in the PALPP group, 13 patients underwent the procedure (two-stage resection rate: 58.3% vs. 76.5%, P = 0.42). There were no significant differences in postoperative complications of one-stage procedures (11.8% vs. 8.3%, P > 0.05) and second-stage resection complication (0% vs. 46.2%, P = 0.05) between the TACE + PVE and PALPP groups. However, the PALPP group demonstrated a shorter time to FLR volume growth for second-stage resection (18.5 days vs. 66 days, P = 0.001) and KGR (58.5 ml/week vs. 7.7 ml/week, P = 0.001). Conclusions: Compared with TACE + PVE, PALPP results in a more significant increase in FLR volume and a higher rate of two-stage resection without increasing postoperative complications.

Cite

CITATION STYLE

APA

Ye, T. W., Fu, T. W., Du, C. F., Yue, R. C., Jiang, Q. T., Zhong, Z. H., … Xiao, Z. Q. (2024). Comparison of percutaneous microwave/radiofrequency ablation liver partition and portal vein embolization versus transarterial chemoembolization and portal vein embolization for planned hepatectomy with insufficient future liver remnant. BMC Cancer, 24(1). https://doi.org/10.1186/s12885-024-12666-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free