Objectives: Little data have been published on the midterm effect of transapical/transfemoral-transcatheter aortic valve replacement (TA-/TF-TAVR) using the Edwards SAPIEN 3 valve (S3). We aimed to compare the outcomes after TA-/TF-TAVR utilizing the S3 (TA-/TF-S3) valve with those after surgical aortic valve replacement utilizing the rapid deployment Edwards INTUITY valve (RD-SAVR). Methods: Between March 2012 and April 2018, 122 patients with aortic stenosis underwent TA-S3, 77 patients underwent TF-S3 and 182 patients underwent RD-SAVR through partial sternotomy at our institution. We conducted clinical and echocardiographic midterm follow-ups. The primary outcomes of the study were the incidence of new pacemakers permanent pacemaker implantation (PPI), the occurrence of paravalvular leakage (PVL) and the hemodynamic performance of the valves. Results: All study groups were at intermediate surgical risk. The 30-day all-cause mortality and stroke rates in the TA-S3, TF-S3, and RD-SAVR groups were 4.1% and 1.6%, 3.9% and 2.6%, and 3.8% and 2.2%, respectively. The RD-SAVR group had significantly smaller PVL and PPI rates than did the TA-/TF-S3 group (p
CITATION STYLE
Useini, D., Beluli, B., Christ, H., Schlömicher, M., Ewais, E., Haldenwang, P., … Strauch, J. (2021). Transcatheter aortic valve replacement using the SAPIEN 3 valve versus surgical aortic valve replacement using the rapid deployment INTUITY valve: Midterm outcomes. Journal of Cardiac Surgery, 36(2), 610–617. https://doi.org/10.1111/jocs.15275