The CAT-CAM socket and quadrilateral socket

  • Gailey R
  • Lawrence D
  • Burditt C
  • et al.
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Twenty unilateral trans-femoral amputees fitted with either the Contoured Adducted Trochanteric-Controlled Alignment Method (CAT-CAM) socket (n=lO) or the quadrilateral (QUAD) socket (n=10), and a "non-amputee" control group (n= 10) participated in the study. Subjects meeting the following criteria were studied: healthy males between the ages of 18 and 55 years, amputation due to non-vascular pathology, an unaffected sound limb, at least six months use of the test prosthesis, and a minimal stump length of 15 cm. Subjects ambulated in two randomized trials separated by 20 minutes of rest at 2 assigned speeds: a pace reflecting normal walking speed (97 m/min=2.5 mph) or a slower speed (48.5 m/min=1.25 mph). Heart rate (HR) and Oxygen uptake (VO2) measured during steady state walking were analyzed via two-way ANOVA. Differences among means were further analyzed using Tukey post hoc and simple effects tests. Significant differences were observed between the control group and CAT-CAM subjects with respect to VOz (pc0.05) and HR (p

Cite

CITATION STYLE

APA

Gailey, R. S., Lawrence, D., Burditt, C., Spyropoulos, P., Newell, C., & Nash, M. S. (1993). The CAT-CAM socket and quadrilateral socket. Prosthetics & Orthotics International, 17(2), 95–100. https://doi.org/10.3109/03093649309164363

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free