Abstract
[Purpose] The purpose of this study was to examine the test-retest reliability of the modified Thomas test using lumbo-pelvic stabilization. [Subjects] Thirteen subjects (male=10, female=3. with hip flexor tightness voluntarily participated in the study. [Methods] The participants underwent the modified Thomas test under three conditions: 1. the general modified Thomas test (GM), 2. active lumbo-pelvic stabilization (ALS), and 3. passive lumbo-pelvic stabilization (PLS). Intra-class correlation coefficients (ICC) were used to determine the test-retest reliability of the knee joint angle measurement under three conditions. The standard error of measurement (SEM) and minimal detectable difference (95% confidence interval) (MDD 95. were calculated for each measurement to assess absolute consistency. [Results] The ALS (ICC = 0. 99. and PLS (ICC = 0. 98. methods for the modified Thomas test were more reliable than GM method (ICC = 0. 97.. The MDD95 score for the ALS method, 2.35 degrees, indicated that a real difference existed between two testing sessions compared with the scores for the PLS (3.70 degrees) and GM methods (4.17 degrees) [Conclusion] Lumbo-pelvic stabilization is one of the considerations for precise measurement and may help to minimize measurement error when evaluating hip flexor tightness using the modified Thomas test.
Author supplied keywords
Cite
CITATION STYLE
Kim, G. M., & Ha, S. M. (2015). Reliability of the modified thomas test using a lumbo-plevic stabilization. Journal of Physical Therapy Science, 27(2), 447. https://doi.org/10.1589/jpts.27.447
Register to see more suggestions