An Improved Duplex Real-Time Quantitative RT-PCR Assay with a Canine Endogenous Internal Positive Control for More Sensitive and Reliable Detection of Canine Parainfluenza Virus 5

4Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

A duplex real-time quantitative reverse transcription-polymerase chain reaction (dqRT-PCR) assay was successfully developed to simultaneously detect canine parainfluenza virus 5 (CPIV5) and a canine endogenous internal positive control (EIPC) in canine clinical samples. Two sets of primers and probes for the CPIV5 L and canine 16S rRNA genes were included in the dqRT-PCR assay to detect CPIV and monitor invalid results throughout the qRT-PCR process. The developed dqRT-PCR assay specifically detected CPIV5 but no other canine pathogens. Furthermore, 16S rRNA was stably amplified by dqRT-PCR assay in all samples containing canine cellular materials. The assay’s sensitivity was determined as below ten RNA copies per reaction, with CPIV5 L gene standard RNA and 1 TCID50/mL with the CPIV5 D008 vaccine strain, which was 10-fold higher than that of the previous HN gene-specific qRT-PCR (HN-qRT-PCR) assays and was equivalent to that of the previous N gene-specific qRT-PCR (N-qRT-PCR) assays, respectively. Moreover, the Ct values of the CPIV5-positive samples obtained using the dqRT-PCR assay were lower than those obtained using the previous HN- and N-qRT-PCR assays, indicating that the diagnostic performance of the dqRT-PCR assay was superior to those of previous HN- and N-qRT-PCR assays. The calculated Cohen’s kappa coefficient values (95% confidence interval) between dqRT-PCR and the HN- or N-specific qRT-PCR assays were 0.97 (0.90–1.03) or 1.00 (1.00–1.00), respectively. In conclusion, the newly developed dqRT-PCR assay with high sensitivity, specificity, and reliability will be a promising diagnostic tool for the detection of CPIV5 in clinical samples and useful for etiological and epidemiological studies of CPIV5 infection in dogs.

Cite

CITATION STYLE

APA

Jeon, G. T., Kim, H. R., Shin, Y. K., Kwon, O. K., Kang, H. E., Kwon, O. D., & Park, C. K. (2023). An Improved Duplex Real-Time Quantitative RT-PCR Assay with a Canine Endogenous Internal Positive Control for More Sensitive and Reliable Detection of Canine Parainfluenza Virus 5. Veterinary Sciences, 10(2). https://doi.org/10.3390/vetsci10020142

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free