Efficiency optimisation of ZVS isolated bidirectional DAB converters

26Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

Abstract

This study presents a control method for isolated bidirectional dual-active-bridge converters to optimise the efficiency by achieving the zero-voltage switching (ZVS) in high-voltage applications, which the switching losses are the major issues. At light-load condition, the duty control algorithm is proposed to achieve the ZVS for all switches while the triple phase shift with ZVS condition is realised at heavy load condition. The operating principles and the design considerations of the proposed control scheme are analysed in detail. A 2 kW prototype converter is built up and tested to verify the feasibility of the proposed control strategy.

Cite

CITATION STYLE

APA

Dung, N. A., Chiu, H. J., Lin, J. Y., Hsieh, Y. C., & Liu, Y. C. (2018). Efficiency optimisation of ZVS isolated bidirectional DAB converters. IET Power Electronics, 11(8), 1499–1506. https://doi.org/10.1049/iet-pel.2017.0723