A five year follow-up of lung function among chemical workers using flow-volume and impedance measurements

9Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Abstract

Impedance of the respiratory system, measured using the forced oscillation technique (FOT), has repeatedly been proposed as a tool for occupational health screening. The aim of this study was to compare the outcome of impedance measurements and flow-volume curves, and to study relationships between lung function decline and specific exposures and smoking. Both measurements were applied in 136 chemical workers from seven main production/personnel groups during a 5 year follow-up (1990-1995). The prevalence of airway obstruction (forced expiratory volume in one second (FEV1) < 80% of predicted) at both time-points was about 5% but did not necessarily include the same subjects. The average decline in FEV1 over 5 yrs was 200 mL (predicted decline 160 mL). Although most impedance parameters correlated to flow-volume parameters in both years, a rapid 5 year decline of FEV1 (> 330 mL) was only accompanied by a significant decrease in the reactance at 8 Hz (X8) and an increase in the resonance frequency (f0). Interestingly, decline in FEV1 was significantly dependent on age, years of employment, pack-years, FEV1, and all impedance parameters at the start in 1990 (r = 0.35; p = 0.01). Similarly, the increase in f0 was significantly dependent on age, years of employment, pack-years, f0, FEV1, forced vital capacity (FVC), peak expiratory flow (PEF) and maximal mid-expiratory flow (MMEF) at the start (r = 0.56; p < 0.01). Those with a rapid decline in FEV1 were relatively more represented among acid workers (relative risk (RR) = 2.14), maintenance workers (RR = 2.1) and bulk/transport workers (RR = 1.78), but none of these was significant. Lung function, however, was significantly lower in the bulk/transport workers (n = 14) compared to the rest, based both on flow-volume (FEV1, FVC) and impedance (X8, f0) measurements. Smoking had a significant effect on most flow-volume parameters but only for frequency dependence among the impedance outcomes. It is concluded that alterations in impedance parameters do reflect changes in flow-volume curves induced by age, smoking and occupational exposure. Therefore, these data are a valuable extension to current cross-sectional data.

Cite

CITATION STYLE

APA

Keman, S., Willemse, B., Wesseling, G. J., Kusters, E., & Borm, P. J. A. (1996). A five year follow-up of lung function among chemical workers using flow-volume and impedance measurements. European Respiratory Journal, 9(10), 2109–2115. https://doi.org/10.1183/09031936.96.09102109

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free