An experimental study of confined masonry walls with varying aspect ratios

69Citations
Citations of this article
56Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Results from an experimental series of seven full-scale confined masonry walls with height-to-length aspect ratios (H/L) from 0.3 up to 2.2 are summarized. Results show that neither the level of axial stress nor the aspect ratio had a significant effect on lateral stiffness. Inelastic behavior of the walls, characterized by normalized stiffness degradation with ductility demand, can be estimated with good accuracy with a bilinear function for a ductility demand up to 4.5. A substantial increase in normalized shear strength was observed for walls with decreasing aspect ratio. A correction factor to the nominal cracking strength was deduced based on differences of the flexural deformations for squat and square walls. The factor was then compared to the experimental normalized strength with good agreement. A new expression for inclined cracking shear that can be used for a wide range of wall aspect ratios is proposed.

Cite

CITATION STYLE

APA

Perez Gavilan, J. J., Flores, L. E., & Alcocer, S. M. (2015). An experimental study of confined masonry walls with varying aspect ratios. Earthquake Spectra, 31(2), 945–968. https://doi.org/10.1193/090712EQS284M