Measurement properties of the 30-second sit-to-stand test in post COVID-19 condition: Results from the PYCNOVID randomised controlled trial

0Citations
Citations of this article
3Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background The 30-second sit-to-stand test (30s-STS) is a frequently used measure of functional capacity in post-COVID-19 condition (PCC), but its measurement properties have not been comprehensively investigated. Methods We used data from the PYCNOVID randomised controlled trial to examine feasibility, safety, test-retest reliability, construct validity (correlations with key symptoms and physical activity), and responsiveness to change of the 30s-STS. Data were collected at screening, at baseline (approximately 2 weeks after screening), and at follow-up (12 weeks after baseline). Using screening and baseline data, agreement was evaluated using Bland-Altman analysis (mean bias and limits of agreement), alongside the intraclass correlation coefficient (ICC) and the minimal detectable change (MDC95). Correlation coefficients were used to assess relationships between the 30s-STS test, physical activity, and key PCC-related symptoms. The minimal important difference (MID) was estimated with data from baseline and at 12-weeks using anchor- and distribution-based methods. Results Data from 150 adults with PCC (74.7% female) were analysed. The 30s-STS was safe (no adverse event) and feasible. Overall, test performance was reduced, 46% of participants had z-score values below the 5th percentile. The test showed good test-retest reliability (ICC 0.82 [95% CI, 0.76 to 0.86]) with no indication for a systematic learning effect; however, the limits of agreement were wide. Mean bias between was 0.84 repetitions (95% CI, 0.26 to 1.42). The MDC95 was 4.25 repetitions. Correlations with physical activity and key PCC-related symptoms were weak. Distribution-based methods yielded MID values between 1.38 and 3.23 repetitions. Change correlations between 30s-STS repetitions and the anchors were insufficient for anchor-based MID calculation. Conclusions The 30s-STS test is feasible, safe, and demonstrates good test-retest reliability. Changes exceeding four repetitions surpass measurement error (MDC95), while distribution-based estimates suggest a provisional MID of two repetitions. Further studies are needed to establish a triangulated MID to better capture patient-relevant change.

Cite

CITATION STYLE

APA

Braun, J., Kopp, J., Künzi, L., Puhan, M. A., Fehr, J. S., & Radtke, T. (2026). Measurement properties of the 30-second sit-to-stand test in post COVID-19 condition: Results from the PYCNOVID randomised controlled trial. PLOS ONE, 21(5 May). https://doi.org/10.1371/journal.pone.0348275

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free