Evaluation of the novel Tanita body-fat analyser to measure body composition by comparison with a four-compartment model

324Citations
Citations of this article
275Readers
Mendeley users who have this article in their library.

Abstract

The Tanita body-fat analyser is a novel device to estimate body fat, based on the principles of bioelectrical impedance. It differs from other impedance systems which use surface electrodes in that the subjects stand bare-footed on a metal sole-plate which incorporates the electrodes, hence impedance is measured through the legs and lower trunk. In 104 men and 101 women (16-78 years and BMI 16-41 kg/m2) the mean bias in body-fat mass measured using the Tanita body-fat analyser was 0.8 (2SD 7.9) kg relative to a four-compartment model. This is comparable to the other prediction techniques tested (conventional tetrapolar impedance -1.3 (2SD 6.9) kg, skinfold thicknesses 0.3 (2SD 7.4) kg, and BMI-based formulas -0.2 (2SD 9.0) kg and -0.6 (2SD 8.5) kg), but the agreement was poorer than for 'reference' methods to measure body fat (density 0.2 (2SD 3.7) kg, total body water -0.9 (2SD 3.4) kg and dual-energy X-ray absorptiometry 0.1 (2SD 5.0) kg). The present paper also describes the derivation of a new prediction equation for the calculation of body composition from the Tanita body-fat analyser. The equation incorporates sex, age, and a log-transformation of height, weight and the measured impedance to predict body fat measured by a four-compartment model. This approach is recommended in the derivation of other prediction equations in body composition analysis. Using this novel prediction equation the residual standard deviations were 4.8 % for men and 3.3 % for women. A similar analysis using data collected with a conventional tetrapolar system yielded residual standard deviations of 4.3 % for men and 3.1 % for women. This demonstrates that the practical simplicity of the novel Tanita method is not associated with a clinically significant decrement in performance relative to a traditional impedance device.

Cite

CITATION STYLE

APA

Jebb, S. A., Cole, T. J., Doman, D., Murgatroyd, P. R., & Prentice, A. M. (2000). Evaluation of the novel Tanita body-fat analyser to measure body composition by comparison with a four-compartment model. British Journal of Nutrition, 83(2), 115–122. https://doi.org/10.1017/S0007114500000155

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free