Comparison of preoxygenation efficiency with Intersurgical Economy and Intersurgical QuadraLite anaesthetic face masks

2Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

Background. Sufficient preoxygenation prevents arterial oxygen desaturation prior to intubation. An optimally sealed facemask is necessary for fast preoxygenation. The study was aimed at comparing the efficiency of preoxygenation using two different face masks. Materials and methods. In 2018, a prospective study was conducted. Patients were classified into two groups: group A – Intersurgical Economy face masks, group B – Intersurgical QuadraLite masks. The circuit was flushed with 100% O2 for 30s, preoxygenation started with flow of 8l/min, FiO2 100. The patients were asked to breathe deeply. Fentanyl (1–2 mcg/kg) was administered to increase mask toleration. Endtidal oxygen concentration (EtO2) ≥90% was the goal. EtO2 was monitored after 30, 60, 90, 120, 180, 210, 240, 270 and 300 seconds. Data was analyzed using the Independent-Samples T-test and the Mann-Whitney-U test. Results. Twelve patients were enrolled in group A and 19 in group B. Differences in sex, age, BMI and Mallampati class in the groups were statistically insignificant (p = 0.13, 0.39, 0.65, 0.43 respectively). Patients assigned to ASA I – 25.8% (n = 8–>2/6), ASA II – 71.0% (n = 22–>10/12), ASA III – 3.2% (n = 1–>0/1), p = 0.64. The success rate of preoxygenation to EtO2 90 with-in 5 min was statistically significantly different in the groups, with 33.3% in group A and 94.7% in group B (p < 0.01). Mean time to EtO2 90 was 228.3 ± 104.0/164.4 ± 84.3. Mean EtO2 after: 30s – 56.0 ± 13.5/69.3 ± 11.2 (p < 0.01); 60s – 63.8 ± 15.3/76.1 ± 11.7 (p = 0.02), 90s – 67.8 ± 17.7/80.7 ± 10.1 (p = 0.03); 120s– 69.6 ± 18.2/83.4 ± 10.0 (p = 0.03), 150s–71.1 ± 19.0/87.1 ± 6.5 (p = 0.01); 180s – 72.9 ± 16.8/88.5 ± 5.3 (p = 0.01), 210s – 72.6 ± 18.0/89.2 ± 5.1 (p < 0.01); 240s – 74.17 ± 15.4/90.0 ± 4.3 (p < 0.01), 270s-76.3 ± 16.3/90.2 ± 3.6; 300s – 77.8 ± 14.6/90.2 ± 1.5 (p < 0.01). Conclusions. Preoxygenation was significantly more efficient and faster with Intersurgical QuadraLite face masks.

Author supplied keywords

Cite

CITATION STYLE

APA

Sakalauskaitė, G., Kauzonas, E., Bukelytė, G., Janulevičienė, R., & Kontrimavičiūtė, E. (2019). Comparison of preoxygenation efficiency with Intersurgical Economy and Intersurgical QuadraLite anaesthetic face masks. Acta Medica Lituanica, 26(1), 11–16. https://doi.org/10.6001/actamedica.v26i1.3950

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free