Quantitative CT-based bone strength parameters for the prediction of novel spinal implant stability using resonance frequency analysis: a cadaveric study involving experimental micro-CT and clinical multislice CT

23Citations
Citations of this article
33Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

BACKGROUND: To predict conventional test forces (peak torque and pull-out force) and a new test force (implant stability quotient [ISQ] value of a spinal pedicle screw) from computed tomography (CT) parameters, including micro-architectural parameters, using high-resolution micro-CT and clinical multislice CT (MSCT) in human cadaveric vertebrae. METHODS: Micro-CT scans before/after screw insertion (n = 68) and MSCT scans before screw insertion (n = 58) of human cadaveric vertebrae were assessed for conventional test forces and ISQ value. Three-dimensional volume position adjustment between pre-insertion micro-CT and MSCT scans and post-insertion scans (micro-CT) was performed to extract the volume of the cancellous bone surrounding the pedicle screw. The following volume bone mineral density and micro-architectural parameters were calculated: bone volume fraction, bone surface density (bone surface/total volume (BS/TV)), trabecular thickness, trabecular separation, trabecular number, structure model index, and number of nodes (branch points) of the cancellous bone network/total volume (NNd/TV) using Spearman's rank correlation coefficient with Bonferroni correction. RESULTS: Conventional test forces showed the strongest correlation with BS/TV: peak torque, ρ = 0.811, p = 4.96 × 10-17(micro-CT) and ρ = 0.730, p = 7.87 × 10-11 (MSCT); pull-out force, ρ = 0.730, p = 1.64 × 10-12 (micro-CT) and ρ = 0.693, p = 1.64 × 10-9 (MSCT). ISQ value showed the strongest correlation with NNd/TV: ρ = 0.607, p = 4.01 × 10-8 (micro-CT) and ρ = 0.515, p = 3.52 × 10-5 (MSCT). CONCLUSIONS: Test forces, including the ISQ value, can be predicted using micro-CT and MSCT parameters. This is useful for establishing a preoperative fixation strength evaluation system.

Cite

CITATION STYLE

APA

Nakashima, D., Ishii, K., Nishiwaki, Y., Kawana, H., Jinzaki, M., Matsumoto, M., … Nagura, T. (2019). Quantitative CT-based bone strength parameters for the prediction of novel spinal implant stability using resonance frequency analysis: a cadaveric study involving experimental micro-CT and clinical multislice CT. European Radiology Experimental, 3(1), 1. https://doi.org/10.1186/s41747-018-0080-3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free