A hooked-collar for bridge piers protection: Flow fields and scour

61Citations
Citations of this article
48Readers
Mendeley users who have this article in their library.

Abstract

A new type of collar, the hooked-collar, was studied through experiments and numerical methods. Tests were conducted using a hooked collar of a width of 1.25b and a height of 0.25b, where b is the bridge-pier width. The hooked-collar efficiency was evaluated by testing different hooked-collar placements within the bridge-pier, which were compared to the bridge-pier without any collar. A double hooked-collar configuration, one placed at the bed level and the other buried 0.25b, was the most efficient at reducing the scour hole. In other cases, a hooked-collar positioned 0.25b above the bed slightly reduced the scour hole and had similar scour patterns when compared to the pier without the hooked-collar. The flow fields along the vertical symmetrical plane in the experiments are also presented. Laboratory experiments and numerical tests show that maximal downflow is highly reduced along with a corresponding decrease in horseshoe vortex strength for the experiments with the hooked-collar, compared to cases without the hooked-collar. The flow fields reveal that the maximum turbulent kinetic energy decreases with the installation of the hooked-collar.

Author supplied keywords

Cite

CITATION STYLE

APA

Chen, S. C., Tfwala, S., Wu, T. Y., Chan, H. C., & Chou, H. T. (2018). A hooked-collar for bridge piers protection: Flow fields and scour. Water (Switzerland), 10(9). https://doi.org/10.3390/w10091251

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free