RF-power and temperature data analysis of 444 patients with primary cervical cancer: Deep hyperthermia using the Sigma-60 applicator is reproducible

30Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

Abstract

Treatment reproducibility is important to guarantee reproducible treatment-outcome, a low-complication rate and efficient treatment procedures. This study evaluated the performance of loco-regional deep hyperthermia with four BSD-2000 configurations during 1990-2005 using the direct available parameters, i.e., temperature and power. Primary cervical cancer patients (n = 444) were all treated within the Sigma-60. Patients were grouped in three weight-groups: <61 kg, 61-70 kg, <70 kg. Different temperature and power indices were extensively analyzed per BSD configuration, per weight-group, and over the time-period. No substantial variations were found for temperature/power indices over the four BSD configurations or for the temperature doses in similar weight-groups. The 'bare' power indices were increased with weight; however, the derivative power-related (W/kg, W/cm2) and temperature indices decreased. Large variations were found in the power-related parameters during 1991-1996 (1st time-period), whereas they were much smaller during 1997-2005 (2nd time-period). The most relevant change noted was the adaptation of the treatment strategy with respect to power modulation. The average frequency of switched-off was 3.4 and 8.9 times/treatment session for the 1st and 2nd time-period, respectively, while the average duration of each switched-off time was 78.2 vs. 38.3 s. The yearly average of vagina T50 was in the range of 39.3-40.2°C (1st time-period) and 40.0-40.5°C (2nd time-period). In 40% of the patients, a positive correlation was found between normalized net integrated power per pelvic area and vagina T50. Good reproducible heating is achieved with the BSD-2000 Sigma-60 irrespective of the regular technological upgrades of the system and variation of trained staff-members.

Cite

CITATION STYLE

APA

Fatehi, D., van der Zee, J., de Bruijne, M., Franckena, M., & van Rhoon, G. C. (2007). RF-power and temperature data analysis of 444 patients with primary cervical cancer: Deep hyperthermia using the Sigma-60 applicator is reproducible. International Journal of Hyperthermia, 23(8), 623–643. https://doi.org/10.1080/02656730701827557

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free