Abstract
The influence of system parameters such as heater power, heater location and mass flow rate on the hysteresis characteristics of a horizontal Rijke tube is presented in this paper. It is observed that a hysteresis zone is present for all the mass flow rates considered in the present study. A power law relation is established between the non-dimensional hysteresis width and the Strouhal number, defined as the ratio between convective time scale and acoustic time scale. The transition to instability in a horizontal Rijke tube is found to be subcritical in all the experiments performed in this study. When heater location is chosen as the control parameter, period-2 oscillations are found for specific values of mass flow rate and heater power.
Author supplied keywords
Cite
CITATION STYLE
Gopalakrishnan, E. A., & Sujith, R. I. (2014). Influence of system parameters on the hysteresis characteristics of a horizontal Rijke tube. In International Journal of Spray and Combustion Dynamics (Vol. 6, pp. 293–316). Multi-Science Publishing Co. Ltd. https://doi.org/10.1260/1756-8277.6.3.293
Register to see more suggestions