Abstract
A north pole NTOF system for neutron spectroscopy is being implemented at the NIF. The design is centered around a fast scintillator with low mass housing fielded 21.6m from target chamber center at θ=18°,φ=304°. The line-of-sight (LOS) features a primary port collimator, two secondary collimators in the intervening concrete floors, and a beam dump with a backscatter shield. Because the detector is being fielded on the roof of the NIF building, diagnostic options such as optical and electrical attenuation are remotely controlled, saving setup time and increasing shot rate. The expected performance of the diagnostic is excellent with high sensitivity to both high-energy reaction-in-flight neutrons as well as lower energy down-scattered neutrons.
Cite
CITATION STYLE
Caggiano, J. A., Barbosa, F., Clancy, T. J., Eckart, M. J., Grim, G., Hartouni, E. P., … Yeoman, M. (2016). Design of a north pole Neutron Time-of-Flight (NTOF) system at NIF. In Journal of Physics: Conference Series (Vol. 717). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/717/1/012087
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.