Optimization and sensitivity enhancement of high-resolution molecular resist for EUV lithography

  • Frommhold A
  • McClelland A
  • Roth J
  • et al.
11Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

© 2016 SPIE. We have recently introduced a new molecular resist system that demonstrates high-resolution capability. A series of studies such as quencher choice and loading was conducted in order to optimize the performance of this material. The optimized conditions allowed patterning 14 nm half-pitch (hp) lines with a line width roughness (LWR) of 3.56 nm at the XIL beamline of the Swiss Light source. Furthermore it was possible to resolve 11 nm hp features with 5.9 nm LWR. First exposure results on an NXE3300 are also presented. We have also begun to investigate the addition of metals to EUV photoresist as a means to increase sensitivity and modify secondary electron blur. Initial results for one of the metal additives show that the sensitivity could be enhanced by up to 60 percent.

Cite

CITATION STYLE

APA

Frommhold, A., McClelland, A., Roth, J., Fallica, R. A., Ekinci, Y., & Robinson, A. P. G. (2016). Optimization and sensitivity enhancement of high-resolution molecular resist for EUV lithography. In Extreme Ultraviolet (EUV) Lithography VII (Vol. 9776, p. 977614). SPIE. https://doi.org/10.1117/12.2219221

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley