3D Multiecho Dixon for the Evaluation of Hepatic Iron and Fat in a Clinical Setting

49Citations
Citations of this article
38Readers
Mendeley users who have this article in their library.

Abstract

Purpose: To prospectively evaluate a new 3D-multiecho-Dixon (3D-ME-Dixon) sequence for the quantification of hepatic iron and fat in a clinical setting. Materials and Methods: In all, 120 patients underwent 1.5T magnetic resonance imaging of the liver between December 2013 and June 2015 including the following three sequences: 3D-ME-Dixon with inline calculation of R2* and proton-density fat-fraction (PDFF) maps, single-voxel-spectroscopy (SVS), 2D multigradient-echo sequence (2D-ME-GRE). SVS and 2D-ME-GRE were used as reference for PDFF and R2*, respectively. R2*- and PDFF-values from 3D-ME-Dixon were compared with those of the reference. Linear regression analysis, Bland–Altman plots, and agreement parameters were calculated. Results: In total, 103 patients were finally included (87 men and 16 women; mean age, 50.51 years); 17/120 were excluded due to fat/water-swaps or R2*-values exceeding the constraint of 400 1/s for 3D-ME-Dixon. A strong correlation (r = 0.992, P < 0.001) between R2* of 3D-ME-Dixon and the reference 2D-ME-GRE was found. Bland–Altman analysis revealed systematically lower values for 3D-ME-Dixon (16.499%). Using an adapted threshold of 57 1/s, 3D-ME-Dixon obtained a positive/negative percentage agreement (PPA/NPA) of 84.4%/91.4% for detecting hepatic iron overload. For hepatic fat the correlation between 3D-ME-Dixon and the reference SVS was strong (r = 0.957, P < 0.001); PPA/NPA was 88.3%/91.4%. Conclusion: The 3D-ME-Dixon sequence is a valuable tool for the evaluation of hepatic iron and fat in a clinical setting. Fat/water-swaps remain a drawback requiring improvements to the implementation and making it necessary to have proven conventional sequences at hand in case of an eventual occurrence. Level of Evidence: 1. Technical Efficacy: Stage 2. J. MAGN. RESON. IMAGING 2017;46:793–800.

Author supplied keywords

Cite

CITATION STYLE

APA

Henninger, B., Zoller, H., Kannengiesser, S., Zhong, X., Jaschke, W., & Kremser, C. (2017). 3D Multiecho Dixon for the Evaluation of Hepatic Iron and Fat in a Clinical Setting. Journal of Magnetic Resonance Imaging, 46(3), 793–800. https://doi.org/10.1002/jmri.25630

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free