At L5A-MRS well installed ESP ING 3200 with 130 stages. From the evaluation results, the ESP ING 3200 does not work well. The pump efficiency is 55%, the pump is in overloaded condition, available stages (130 stages) are less than the required minimum stages (174 stages) to lift the fluid up to the surface. It is necessary to do electric submersible pump redesign. Pump design is ESP ING 4000, 145 stages available, Q design 4450 bpd, 60 Hz, pump efficiency 66%, on PSD 4000 ft.