Comparison of liquid chromatography mass spectrometry and enzyme-linked immunosorbent assay methods to measure salivary cotinine levels in ill children

9Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.

Abstract

Objective: Cotinine is the preferred biomarker to validate levels of tobacco smoke exposure (TSE) in children. Compared to enzyme-linked immunosorbent assay methods (ELISA) for quantifying cotinine in saliva, the use of liquid chromatography tandem mass spectrometry (LCMS/ MS) has higher sensitivity and specificity to measure very low levels of TSE. We sought to compare LC-MS/MS and ELISA measures of cotinine in saliva samples from children overall and the associations of these measures with demographics and TSE patterns. Method: Participants were nonsmoking children (N = 218; age mean (SD) = 6.1 (5.1) years) presenting to a pediatric emergency department. Saliva samples were analyzed for cotinine using both LC-MS/MS and ELISA. Limit of quantitation (LOQ) for LC-MS/MS and ELISA was 0.1 ng/ml and 0.15 ng/ml, respectively. Results: Intraclass correlations (ICC) across methods = 0.884 and was consistent in sex and age subgroups. The geometric mean (GeoM) of LC-MS/MS = 4.1 (range: < LOQ) which was lower (p < 0.0001) than the ELISA GeoM = 5.7 (range: < LOQ). Similar associations of cotinine concentrations with age (β < -0.10, p < 0.0001), demographic characteristics (e.g., income), and number of cigarettes smoked by caregiver (β > 0.07, p < 0.0001) were found regardless of cotinine detection method; however, cotinine associations with sex and race/ethnicity were only found to be significant in models using LC-MS/MS-derived cotinine. Conclusions: Utilizing LC-MS/MS-based cotinine, associations of cotinine with sex and race/ethnicity of child were revealed that were not detectable using ELISA-based cotinine, demonstrating the benefits of utilizing the more sensitive LC-MS/MS assay for cotinine measurement when detecting low levels of TSE in children.

Cite

CITATION STYLE

APA

Mahabee-Gittens, E. M., Mazzella, M. J., Doucette, J. T., Merianos, A. L., Stone, L., Wullenweber, C. A., … Matt, G. E. (2020). Comparison of liquid chromatography mass spectrometry and enzyme-linked immunosorbent assay methods to measure salivary cotinine levels in ill children. International Journal of Environmental Research and Public Health, 17(4). https://doi.org/10.3390/ijerph17041157

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free