Abstract
This paper presents a comprehensive approach to the statistical characterization of impulse breakdown voltage under the effect of a DC sweep voltage. Several goodness-of-fit tests are applied to up-and-down test results obtained in the air-insulated rod-plane gap. Three distributions, normal, logistic, and Gumbel, are compared by means of the Kolmogorov-Smirnov goodness-of-fit test, and logistic distribution is also compared to 3-parameter Weibull distributions using the likelihood ratio test. Logistic distribution is found to be a possible alternative to normal and 3-parameter Weibull distributions. © TÜBİTAK.
Author supplied keywords
Cite
CITATION STYLE
Demir, M., & Koraşli, C. (2014). Statistical approach for determining impulse breakdown voltage distribution under DC sweep voltage. Turkish Journal of Electrical Engineering and Computer Sciences, 22(1), 12–24. https://doi.org/10.3906/elk-1206-56