Abstract
This paper proposes some consequent‐pole (CP) modular permanent magnet (PM) machines with different flux gap (FG) widths and slot/pole number combinations. The corresponding inset modular PM machines having the same magnet volume are also presented for comparison. It has been demonstrated that the output torques of the consequent pole modular machines are always higher than those of the inset modular machines regardless of FG widths and slot/pole number combinations. Other electromagnetic performances such as back‐EMF, cogging torque, and iron losses etc. are calculated by 2D FEA software and compared as well. The advantages and disadvantages of consequent and inset modular PM machines are summarised here.
Cite
CITATION STYLE
Ren, B., Li, G., Zhu, Z., Foster, M., & Stone, D. (2019). Performance comparison between consequent‐pole and inset modular permanent magnet machines. The Journal of Engineering, 2019(17), 3951–3955. https://doi.org/10.1049/joe.2018.8200