Final 5-year outcomes following aortic valve replacement with a RESILIA™ tissue bioprosthesis

67Citations
Citations of this article
43Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: Long-term durability of bioprosthetic valves is predominantly limited by structural valve deterioration. RESILIA™ tissue has exhibited reduced calcification in pre-clinical and early clinical studies. This study evaluated the 5-year clinical and haemodynamic outcomes of an aortic valve with this tissue. Methods: This was a prospective, non-randomized, single-arm study of 133 patients implanted with a RESILIA aortic bioprosthesis between July 2011 and February 2013 at 2 sites in Poland. Clinical outcomes and haemodynamic performance were assessed annually for 5 years post-implant. Safety events were adjudicated by a Clinical Events Committee and echocardiographic data were assessed by an independent core laboratory. Results: Mean patient age was 65.3 ± 13.5 years, with 34 patients (25.6%) ≤60. The mean follow-up was 4.2 ± 1.5 years. Early (≤30 days) and late (>30 days) all-cause mortality were 2.3% (N = 3) and 3.2%/late patients-years (N = 18) respectively. Early events included thromboembolism in 3 patients (2.3%). Late valve-related events included endocarditis in 1 patient, which led to explant, and valve thrombosis in another patient. There were no events of structural valve deterioration throughout the study. At 5 years, mean gradient was 14.8 ± 7.6 mmHg and effective orifice area was 1.4 ± 0.5 cm2, a marked improvement over baseline values. All New York Heart Association class III patients and most class II patients at baseline had improved classifications at 5 years. Conclusions: The bioprosthesis with RESILIA tissue demonstrated a good safety profile with excellent haemodynamic performance over 5 years of follow-up. These encouraging outcomes warrant additional investigation of this novel tissue.

Cite

CITATION STYLE

APA

Bartus, K., Litwinowicz, R., Bilewska, A., Stapor, M., Bochenek, M., Rozanski, J., … Kapelak, B. (2021). Final 5-year outcomes following aortic valve replacement with a RESILIATM tissue bioprosthesis. European Journal of Cardio-Thoracic Surgery, 59(2), 434–441. https://doi.org/10.1093/ejcts/ezaa311

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free