Mechanical ventilation in the ICU- is there a gap between the time available and time used for nurse-led weaning?

14Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Mechanical ventilation (MV) is a key component in the care of critically ill and injured patients. Weaning from MV constitutes a major challenge in intensive care units (ICUs). Any delay in weaning may increase the number of complications and leads to greater expense. Nurse-led, protocol-directed weaning has become popular, but it remains underused. The aim of this study was to identify and quantify discrepancies between the time available for weaning and time actually used for weaning. Further, we also wished to analyse patient and systemic factors associated with weaning activity.Methods: This retrospective study was performed in a 12-bed general ICU at a university hospital. Weaning data were collected from 68 adult patients on MV and recorded in terms of ventilator-shifts. One ventilator-shift was defined as an 8-hour nursing shift for one MV patient.Results: Of the 2000 ventilator-shifts analysed, 572 ventilator-shifts were available for weaning. We found that only 46% of the ventilator shifts available for weaning were actually used for weaning. While physician prescription of weaning was associated with increased weaning activity (p < 0.001), a large amount (22%) of weaning took place without physician prescription. Both increased nursing workload and night shifts were associated with reduced weaning activity. During the study period there was a significant increase in performed weaning, both when prescribed or not (p < 0.001).Conclusion: Our study identified a significant gap between the time available and time actually used for weaning. While various patient and systemic factors were linked to weaning activity, the most important factor in our study was whether the intensive care nurses made use of the time available for weaning. © 2008 Hansen et al; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Hansen, B. S., Fjælberg, W. T. M., Nilsen, O. B., Lossius, H. M., & Søreide, E. (2008). Mechanical ventilation in the ICU- is there a gap between the time available and time used for nurse-led weaning? Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 16(1). https://doi.org/10.1186/1757-7241-16-17

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free