Initial experience of using a large-bore (0.096″ inner diameter) access catheter in neurovascular interventions

4Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Introduction: The purpose of this study was to report our initial experience of using a large-bore (0.096″ inner diameter) access catheter in neurovascular interventions. Methods: Data were retrospectively collected from 5 sites in the US for neurovascular procedures performed using a large-bore access catheter. The effectiveness outcome was technical success, defined as the access catheter's successfully reaching its target vessel without conversion to direct carotid puncture or to a smaller-bore access catheter and successfully completing the intended neurointervention. Results: One hundred and thirteen procedures performed in 112 patients were included in this study. The mean age of the patients was 67.5 years (SD 16.2), and about half (49.1%) were female. The most common primary access sites were the femoral (64.6%) or radial (32.7%) artery. Challenging anatomic variations included severe vessel tortuosity (26/81, 32.1%), type II aortic arch (17/88, 19.3%), type III aortic arch (14/88, 15.9%), bovine arch (16/104, 15.4%), severe angle (<30°) between the subclavian and target vessel (11/74, 14.9%), and subclavian loop (7/79, 8.9%). The median access time to branch view was 18 min (IQR 11-28, N = 75). The technical success rate was 94.7%. Two dissections (1.8%) were related to the large-bore access catheter. Access site complications occurred in 2 patients (1.8%). Four additional symptomatic periprocedural complications not related to the large-bore access catheter occurred (7.1%). Conclusion: For neurovascular interventions, a 0.096″ inner diameter access catheter could be used with both femoral and radial arterial approaches, had a high technical success rate, and had a low rate of periprocedural complications.

Cite

CITATION STYLE

APA

Starke, R. M., Abecassis, I. J., Saini, V., Matouk, C. C., Hassan, A. E., Siddiqui, A. H., & Frei, D. F. (2024). Initial experience of using a large-bore (0.096″ inner diameter) access catheter in neurovascular interventions. Interventional Neuroradiology, 30(3), 372–379. https://doi.org/10.1177/15910199221127074

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free