Comparison of pulse contour, aortic Doppler ultrasound and bioelectrical impedance estimates of stroke volume during rapid changes in blood pressure

11Citations
Citations of this article
44Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

New Findings: What is the central question of this study? Pulse contour analysis of the finger arterial pressure by Windkessel modelling is commonly used to estimate stroke volume continuously. But is it valid during dynamic changes in blood pressure? What is the main finding and its importance? Second-by-second analysis revealed that pulse contour analysis underestimated stroke volume by up to 25% after standing from a squat, and 16% after standing thigh-cuff release, when compared with aortic Doppler ultrasound estimates. These results reveal that pulse contour analysis of stroke volume should be interpreted with caution during rapid changes in physiological state. Abstract: Dynamic measurements of stroke volume (SV) and cardiac output provide an index of central haemodynamics during transitional states, such as postural changes and onset of exercise. The most widely used method to assess dynamic fluctuations in SV is the Modelflow method, which uses the arterial blood pressure waveform along with age- and sex-specific aortic properties to compute beat-to-beat estimates of aortic flow. Modelflow has been validated against more direct methods in steady-state conditions, but not during dynamic changes in physiological state, such as active orthostatic stress testing. In the present study, we compared the dynamic SV responses from Modelflow (SVMF), aortic Doppler ultrasound (SVU/S) and bioelectrical impedance analysis (SVBIA) during two different orthostatic stress tests, a squat-to-stand (S-S) transition and a standing bilateral thigh-cuff release (TCR), in 15 adults (six females). Second-by-second analysis revealed that when compared with estimates of SV by aortic Doppler ultrasound, Modelflow underestimated SV by up to 25% from 3 to 11 s after standing from the squat position and by up to 16% from 3 to 7 s after TCR (P < 0.05). The SVMF and SVBIA were similar during the first minute of the S-S transition, but were different 3 s after TCR and at intermittent time points between 34 and 44 s (P < 0.05). These findings indicate that the physiological conditions elicited by orthostatic stress testing violate some of the inherent assumptions of Modelflow and challenge models used to interpret bioelectrical impedance responses, resulting in an underestimation in SV during rapid changes in physiological state.

Cite

CITATION STYLE

APA

Gibbons, T. D., Zuj, K. A., Peterson, S. D., & Hughson, R. L. (2019). Comparison of pulse contour, aortic Doppler ultrasound and bioelectrical impedance estimates of stroke volume during rapid changes in blood pressure. Experimental Physiology, 104(3), 368–378. https://doi.org/10.1113/EP087240

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free