Gamma Index Analysis as a Patient-Specific Quality Assurance Tool for High-Precision Radiotherapy: A Clinical Perspective of Single Institute Experience

  • Das S
  • Kharade V
  • Pandey V
  • et al.
N/ACitations
Citations of this article
68Readers
Mendeley users who have this article in their library.

Abstract

Purpose Patient-specific quality assurance (QA) by gamma (γ) analysis is an important component of high-precision radiotherapy. It is important to standardize institute-specific protocol. In this study, we describe our institutional experience of patient-specific QA for high-precision radiotherapy from a clinical perspective. Methods The planning data of 56 patients treated with intensity-modulated radiotherapy (IMRT)/volumetric modulated arc therapy (VMAT) were included. γ index analysis was done using Octavius 4D IMRT QA phantom (PTW, Freiburg, Germany) using 3 mm/3% criteria. Local, global, and volumetric gammas were calculated and compared. The relationship of γ index in the transverse, coronal, and sagittal direction and anatomical region of treatment was explored. Results Global three-dimensional (3D) γ indices in the coronal, sagittal, and transverse axes were 96.73 ± 2.35, 95.66 ± 3.01, and 93.36 ± 4.87 (p < 0.05). The average local two-dimensional (2D) γ index was 78.23 ± 5.44 and the global γ index was 92.41 ± 2.41 (p < 0.005). The average local 3D γ index was 84.99 ± 4.24 and the global 3D γ index was 95.25 ± 1.72 (p < 0.005, paired t-test). The average local volumetric γ index was 84.29 ± 4.73 and the global volumetric γ index was 95.96 ± 2.08 (p < 0.005). 3D global gamma index was significantly different in different anatomical regions (p < 0.05). Conclusion Our study shows that γ index analysis is a useful parameter for routine clinical IMRT QA. The choice of type of γ index depends on the context of use and degree of stringency in measurement. Average 2D and 3D global γ were different in anatomical regions. The average 3D γ index was significantly different in axes. No difference was observed with techniques of IMRT/VMAT. Localization of failed points in CT anatomy can be advantageous for clinical decision-making.

Cite

CITATION STYLE

APA

Das, S., Kharade, V., Pandey, V., KV, A., Pasricha, R. K., & Gupta, M. (2022). Gamma Index Analysis as a Patient-Specific Quality Assurance Tool for High-Precision Radiotherapy: A Clinical Perspective of Single Institute Experience. Cureus. https://doi.org/10.7759/cureus.30885

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free