Changes in platelet function and coagulation after transcatheter aortic valve implantation evaluated with thromboelastography

7Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

Abstract

Introduction The possibility of hypercoagulability during the perioperative period of transcatheter aortic valve implantation (TAVI) has been noted; however, there is still a controversy regarding the appropriate perioperative antithrombotic therapy. The study investigated coagulation and platelet functions during the TAVI perioperative period using thromboelastography (TEG) 6s platelet mapping. Methods A prospective observational study was conducted on 25 patients undergoing TAVI. TEG platelet mapping was performed at three time points: on admission to the operating room (before heparinisation), on postoperative day (POD) 1 and on POD 3. Perioperative changes observed included: maximum clot strength (MA HKH), clot strength without platelet function (MA ActF), time to initiation of clots formation by coagulation factors (R HKH) and platelet function (G p). G p is activated by thrombin, and not affected by antiplatelet agents. It is calculated as [(5000×MA HKH)/(100 - MA HKH)] - [(5000×MA ActF)/(100 - MA ActF)]. Finally, MA ADP/AA and G ADP/AA, which reflect clot strength and platelet aggregation mediated by ADP/thromboxane A 2 receptors, respectively, were also examined using the same method as for G p. Results MA HKH continued to decrease until POD 3, indicating antithrombotic change after TAVI. G p continuously decreased for 3 days after TAVI, while MA ActF increased significantly on POD 3. Furthermore, R HKH shortened on POD 1 and POD 3, suggesting increased coagulation capacity after TAVI. Finally, G ADP in clopidogrel-naive patients was reduced for 3 days after TAVI, while G AA in aspirin-naive patients showed no significant change perioperatively. Conclusions In this study involving TEG platelet mapping, coagulation capacity increased while platelet function decreased, resulting in antithrombotic change for 3 days after TAVI. The ADP receptor system may be implicated in the decreased platelet function. These results may be useful for considering optimal perioperative antithrombotic therapy in TAVI.

Cite

CITATION STYLE

APA

Harada, M., Sajima, T., Onimaru, T., Honjo, T., Hioki, H., Watanabe, Y., & Sawamura, S. (2022). Changes in platelet function and coagulation after transcatheter aortic valve implantation evaluated with thromboelastography. Open Heart, 9(2). https://doi.org/10.1136/openhrt-2022-002132

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free