Abstract

Closed-loop nanorobot control performance is a key challenge on the way to high-throughput nanohandling. Currently, the limited update rate, long latency and unpredictable jitter of tracking based on scanning electron microscope images are a major bottleneck for such closed-loop control. A new approach for high-speed position sensing relying on line scans of a scanning electron microscope is adapted into the control loop of a mobile nanorobot. Several evaluation measurements show the system's unprecedented performance in terms of speed, resolution and accuracy. In only 60 ms, the employed mobile nanorobot can be positioned with a precision of 20nm in multiple degrees of freedom.

Author supplied keywords

Cite

CITATION STYLE

APA

Jasper, D., Diederichs, C., Edeler, C., & Fatikow, S. (2011). High-speed nanorobot position control inside a scanning electron microscope. ECTI Transactions on Electrical Engineering, Electronics, and Communications, 9(1), 177–186. https://doi.org/10.37936/ecti-eec.201191.172471