Direct measurement of high-density lipoprotein cholesterol in serum with polyethylene glycol-modified enzymes and sulfated α-cyclodextrin

407Citations
Citations of this article
94Readers
Mendeley users who have this article in their library.
Get full text

Abstract

We have developed an automated method for measuring high-density lipoprotein (HDL)-cholesterol in serum without prior separation, using polyethylene glycol (PEG)-modified enzymes and sulfated α-cyclodextrin. When cholesterol esterase and cholesterol oxidase enzymes were modified with PEG, they showed selective catalytic activities towards lipoprotein fractions, with the reactivity increasing in the order: low-density lipoprotein < very- low-density lipoprotein ≃ chylomicron < HDL. In the presence of magnesium ions, α-cyclodextrin sulfate reduced the reactivity of cholesterol, especially in chylomicrons and very-low-density lipoprotein, without the need for precipitation of those lipoprotein fractions. The combination of PEG- modified enzymes with α-cyclodextrin sulfate provided selectivity for the determination of HDL-cholesterol in serum in the presence of a small amount of dextran sulfate without the need for precipitation of lipoprotein aggregates. The results of the HDL-cholesterol assayed in serum by this direct method correlated well with those obtained by precipitation-based methods and also that by an ultracentrifugation method.

Cite

CITATION STYLE

APA

Sugiuchi, H., Uji, Y., Okabe, H., Irie, T., Uekama, K., Kayahara, N., & Miyauchi, K. (1995). Direct measurement of high-density lipoprotein cholesterol in serum with polyethylene glycol-modified enzymes and sulfated α-cyclodextrin. Clinical Chemistry, 41(5), 717–723. https://doi.org/10.1093/clinchem/41.5.717

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free