The Relationship Between the Permeability and the Performance of Carrier-Based Dry Powder Inhalation Mixtures: New Insights and Practical Guidance

23Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The permeability of a powder bed reflects its particle size distribution, shape, packing, porosity, cohesivity, and tensile strength in a manner relevant to powder fluidization. The relationship between the permeability and the performance of carrier-based dry powder inhalation (DPI) mixtures has, however, aroused controversy. The current study sought to gain new insights into the relationship and to explore its potential applications. We studied eight lactose materials as DPI carriers. The carriers covered a broad permeability range of 0.42–13.53 D and moreover differed in particle size distribution, particle shape, crystal form, and/or porosity. We evaluated the performance of inhalation mixtures of each of these carriers and fluticasone propionate after aerosolization from an Aerolizer®, a model turbulent-shear inhaler, at a flow rate of 60 L/min. Starting from the high permeability side, the inhalation mixture performance increased as the carrier permeability decreased until optimum performance was reached at permeability of ~ 3.2 D. Increased resistance to air flow strengthens aerodynamic dispersion forces. The inhalation mixture performance then decreased as the carrier permeability further decreased. Very high resistance to air flow restricts powder dispersion. The permeability accounted for effects of carrier size, shape, and macroporosity on the performance. We confirmed the relationship by analysis of two literature permeability–performance datasets, representing measurements that differ from ours in terms of carrier grades, drug, technique used to determine permeability, turbulent-shear inhaler, and/or aerosolization flow rate. Permeability provides useful information that can aid development of DPI mixtures for turbulent-shear inhalers. A practical guidance is provided.

Cite

CITATION STYLE

APA

Shalash, A. O., Khalafallah, N. M., Molokhia, A. M., & Elsayed, M. M. A. (2018). The Relationship Between the Permeability and the Performance of Carrier-Based Dry Powder Inhalation Mixtures: New Insights and Practical Guidance. AAPS PharmSciTech, 19(2), 912–922. https://doi.org/10.1208/s12249-017-0898-7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free