Energy consumption of agitators in activated sludge tanks - Actual state and optimization potential

14Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

Abstract

Depending on design capacity, agitators consume about 5 to 20% of the total energy consumption of a wastewater treatment plant. Based on inhabitant-specific energy consumption (kWh PE120-1 a-1; PE120 is population equivalent, assuming 120 g chemical oxygen demand per PE per day), power density (W m-3) and volume-specific energy consumption (Wh m-3 d-1) as evaluation indicators, this paper provides a sound contribution to understanding energy consumption and energy optimization potentials of agitators. Basically, there are two ways to optimize agitator operation: the reduction of the power density and the reduction of the daily operating time. Energy saving options range from continuous mixing with low power densities of 1 W m-3 to mixing by means of short, intense energy pulses (impulse aeration, impulse stirring). However, the following correlation applies: the shorter the duration of energy input, the higher the power density on the respective volume-specific energy consumption isoline. Under favourable conditions with respect to tank volume, tank geometry, aeration and agitator position, mixing energy can be reduced to 24 Wh m-3 d-1 and below. Additionally, it could be verified that power density of agitators stands in inverse relation to tank volume.

Cite

CITATION STYLE

APA

Füreder, K., Svardal, K., Frey, W., Kroiss, H., & Krampe, J. (2018). Energy consumption of agitators in activated sludge tanks - Actual state and optimization potential. Water Science and Technology, 77(3), 800–808. https://doi.org/10.2166/wst.2017.596

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free