Abstract

Background Carbapenem-resistant Klebsiella pneumoniae infections are increasingly prevalent in North American hospitals. We describe an outbreak of carbapenem-resistant K. pneumoniae containing the bla OXA-232 gene transmitted by contaminated duodenoscopes during endoscopic retrograde cholangiopancreatography (ERCP) procedures. Methods An outbreak investigation was performed when 9 patients with bla OXA-232 carbapenem-resistant K. pneumoniae infections were identified at a tertiary care hospital. The investigation included 2 case-control studies, review of duodenoscope reprocessing procedures, and culture of devices. Carbapenem-resistant Enterobacteriacieae (CRE) isolates were evaluated with polymerase chain reaction analysis for carbapenemase genes, and isolates with the bla OXA-232 gene were subjected to whole-genome sequencing and chromosome single-nucleotide polymorphism analysis. On recognition of ERCP as a key risk factor for infection, targeted patient notification and CRE screening cultures were performed. Results Molecular testing ultimately identified 17 patients with bla Oxa-232 carbapenem-resistant K. pneumoniae isolates, including 9 with infections, 7 asymptomatic carriers who had undergone ERCP, and 1 additional patient who had been hospitalized in India and was probably the initial carrier. Two case-control studies established a point-source outbreak associated with 2 specific duodenoscopes. A field investigation of the use, reprocessing, and storage of deuodenoscopes did not identify deviations from US Food and Drug Administration or manufacturer recommendations for reprocessing. Conclusions This outbreak demonstrated the previously underappreciated potential for duodenoscopes to transmit disease, even after undergoing high-level disinfection according to manufacturers' guidelines.

Cite

CITATION STYLE

APA

Humphries, R. M., Yang, S., Kim, S., Muthusamy, V. R., Russell, D., Trout, A. M., … Rubin, Z. A. (2017). Duodenoscope-Related Outbreak of a Carbapenem-Resistant Klebsiella pneumoniae Identified Using Advanced Molecular Diagnostics. Clinical Infectious Diseases, 65(7), 1159–1166. https://doi.org/10.1093/cid/cix527

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free