Immunoaffinity column cleanup with liquid chromatography for determination of aflatoxin B1 in corn samples: Interlaboratory study

33Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.
Get full text

Abstract

An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin 61 levels in corn samples, enforced by European Union legislation. A test portion was extracted with methanol-water (80 + 20); the extract was filtered, diluted with phosphate-buffered saline solution, filtered on a microfiber glass filter, and applied to an immunoaffinity column. The column was washed with deionized water to remove interfering compounds, and the purified aflatoxin 61 was eluted with methanol. Aflatoxin Bi was separated and determined by reversed-phase LC with fluorescence detection after either pre- or postcolumn derivatization. Precolumn derivatization was achieved by generating the trifluoroacetic acid derivative, used by 8 laboratories. The postcolumn derivatization was achieved either with pyridinium hydrobromide perbromide, used by 16 laboratories, or with an electrochemical cell by the addition of bromide to the mobile phase, used by 5 laboratories. The derivatization techniques used were not significantly different when compared by the Student's t-test; the method was statistically evaluated for all the laboratories. Five corn sample materials, both spiked and naturally contaminated, were sent to 29 laboratories (22 Italian and 7 European). Test portions were spiked with aflatoxin B 1 at levels of 2.00 and 5.00 ng/g. The mean values for recovery were 82% for the low level and 84% for the high contamination level. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the values for relative standard deviation for repeatability (RSDr) ranged from 9.9 to 28.7%. The values for relative standard deviation for reproducibility (RSDR) ranged from 18.6 to 36.8%. The method demonstrated acceptable within- and between-laboratory precision for this matrix, as evidenced by the HorRat values.

Cite

CITATION STYLE

APA

Brera, C., Debegnach, F., Minardi, V., Pannunzi, E., De Santis, B., Miraglia, M., … Zanon, F. (2007). Immunoaffinity column cleanup with liquid chromatography for determination of aflatoxin B1 in corn samples: Interlaboratory study. Journal of AOAC International, 90(3), 765–772. https://doi.org/10.1093/jaoac/90.3.765

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free