Incidence and risk factors for central venous access device failure in hospitalized adults: A multivariable analysis of 1892 catheters

9Citations
Citations of this article
42Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Central venous access devices (CVADs) allow intravenous therapy, haemodynamic monitoring and blood sampling but many fail before therapy completion. Objective: To quantify CVAD failure and complications; and identify risk factors. Designs, Settings, and Participants: Secondary analysis of multicentre randomised controlled trial including patients aged ≥16 years with a non-tunnelled CVAD (NTCVAD), peripherally-inserted central catheter (PICC) or tunnelled CVAD (TCVAD). Primary outcome was incidence of all-cause CVAD failure (central line-associated bloodstream infection [CLABSI], occlusion, accidental dislodgement, catheter fracture, thrombosis, pain). Secondary outcomes were CLABSI, occlusion and dislodgement. Cox regression was used to report time-to-event associations. Results: In 1892 CVADs, all-cause failure occurred in 10.2% of devices: 49 NTCVADs (6.1%); 100 PICCs (13.2%); 44 TCVADs (13.4%). Failure rates for CLABSI, occlusion and dislodgement were 5.3%, 1.8%, and 1.7%, respectively. Independent CLABSI predictors were blood product administration through PICCs (hazard ratio (HR) 2.62, 95% confidence interval (CI) 1.24–5.55); and in TCVADs, one or two lumens, compared with three to four (HR 3.36, 95%CI 1.68–6.71), intravenous chemotherapy (HR 2.96, 95%CI 1.31–6.68), and diabetes (HR 3.25, 95%CI 1.40–7.57). Independent factors protective for CLABSI include antimicrobial NTCVADs (HR 0.23, 95%CI 0.08–0.63) and lipids in TCVADs (HR 0.32, 95%CI 0.14–0.72). NTCVADs inserted at another hospital (HR 7.06, 95%CI 1.48–33.7) and baseline infection in patients with PICCs (HR 2.72, 95%CI 1.08–6.83) were predictors for dislodgement. No independent occlusion predictors were found. Modifiable risk factors were identified for CVAD failure, which occurred for 1-in-10 catheters. Strict infection prevention measures and improved CVAD securement could reduce CLABSI and dislodgement risk.

Cite

CITATION STYLE

APA

Corley, A., Royle, R. H., Marsh, N., Larsen, E. N., Playford, E. G., McGrail, M. R., … Rickard, C. M. (2024). Incidence and risk factors for central venous access device failure in hospitalized adults: A multivariable analysis of 1892 catheters. Journal of Hospital Medicine, 19(10), 905–917. https://doi.org/10.1002/jhm.13414

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free