Sensitivity analyses for the atmospheric dry deposition of total PCDD/Fs-TEQ for Handan and Kaifeng cities, China

5Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

During the period 2016–2017, the atmospheric wet, dry, and total deposition fluxes and scavenging ratios of the total PCDD/Fs-WHO2005-TEQ in Handan and Kaifeng were investigated. In addition, a sensitivity analysis for the dry deposition fluxes of the total PCDD/Fs-WHO2005-TEQ was conducted. The annual wet deposition fluxes of total PCDD/Fs-WHO2005-TEQ in Handan ranged between 51.1 and 83.5 and averaged 72.3 pg WHO2005-TEQ m–2 year–1, which was approximately 1.04 times of magnitude higher than that in Kaifeng (69.3 pg WHO2005-TEQ m–2 year–1). From 2016– 2017, the contribution fraction of dry deposition to the total PCDD/Fs-WHO2005-TEQ deposition flux ranged between 60.8% and 100% and averaged 80.4%. Dry deposition fluxes were more dominant than wet deposition fluxes. In terms of the seasonal variations in total PCDD/Fs-WHO2005-TEQ dry deposition fluxes (the mean values for 2016 and 2017) in Handan, those in spring, summer, fall, and winter were 1084, 563, 964, and 1325 pg WHO2005-TEQ m–2 month–1, respectively, while in Kaifeng, they were 963, 428, 715, and 1016 pg WHO2005-TEQ m–2 month–1, respectively. The total PCDD/Fs-WHO2005-TEQ deposition fluxes in winter was approximately 2.0 times of magnitude higher than that in summer. The sensitivity analysis of total PCDD/FsWHO2005-TEQ dry deposition fluxes in Handan and Kaifeng showed that the PM10 concentration was the most positively correlated sensitive factor. When ΔP/P was changed from 0% to +50%, ΔS/S responded from 0% to +46.1% and +46.3%, respectively. The second positively correlated sensitive factor was the PM2.5 concentration, where when ΔP/P was changed from 0% to +50%, ΔS/S responded from 0% to +47.8% and +40.8%, respectively. For PCDD/Fs mass concentration, when ΔP/P was changed from 0% to +50%, ΔS/S responded from 0% to +32.2% and +28.1%, respectively. This was followed by the atmospheric temperature, and its effect was negatively correlated. When ΔP/P was changed from –50% to +50%, ΔS/S responded from +46.4% to –26.9% and +57.0% to –30.5%, respectively. The results of this study provide useful information that can be used to achieve more insights into both atmospheric deposition of total PCDD/Fs-WHO2005-TEQ and the sensitive factors for dry deposition fluxes.

Cite

CITATION STYLE

APA

Zhao, R., Cui, K., Wang, W., Wang, L. C., & Wang, Y. F. (2018). Sensitivity analyses for the atmospheric dry deposition of total PCDD/Fs-TEQ for Handan and Kaifeng cities, China. Aerosol and Air Quality Research, 18(5), 1255–1269. https://doi.org/10.4209/aaqr.2018.03.0109

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free