Clinical Performances of Pure TB-Lamp Kit for M. tuberculosis Complex Detection in Sputum Samples

  • N’guessan K
  • Adegbele J
  • Coulibaly I
  • et al.
N/ACitations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

Tuberculosis represents a main concern for public health worldwide. In poor countries, the most prevalent method for bacteriological confirmation remains Smear Sputum Microscopy (SSM). This study objective was to assess clinical performances of Loop Mediated Isothermal Amplification for TB detection (Lamp-TB). Sputum of patients presenting symptoms consistent with tuberculosis were collected according to the National Tuberculosis Control Programme guidelines in Centre Antituberculeux de Yopougon. SSM after Ziehl-Neelsen staining and TB-Lamp were blindly performed with spot spu-tum specimen. Samples, transported at Institut Pasteur de Côte d'Ivoire were decontaminated according to N-acetyl-L-cystein (NALC) method. In Myco-bacteria Growth Indicator Tube (MGIT), 500 µl of pellet were inoculated and incubated in MGIT 960 instrument. MPT64 antigen was detected on positive culture. Of 500 patients enrolled, 469 were included. Clinical isolates of M. tuberculosis Complex were detected for 157 (33.5%). Comparatively to culture , Sensitivity and Specificity of SSM were 86% (95% Confidence interval (CI): 81%-91%) 96% (95%IC: 94%-98%) respectively. TB-Lamp Sensitivity was 92% (95%CI: 88%-96%), and Specificity 94% (95%CI: 91%-97%). Positive Predictive Value of SSM and TB-Lamp was 91.8% and 88.8% respectively. Negative Predictive Value of TB-Lamp assay was 95.7% whereas this of SSM was 93.3%. Positive Likelihood Ratio was 15.3 for TB-Lamp and 21.5 for SSM 21.5 whereas negative Likelihood of TB-Lamp was lower than SSM. Active tuberculosis was detected in162/469 (34.5%) with TB-Lamp and 147 (31.3%) with SSM. TB-Lamp assay performances estimated from sputum samples may improve detection of active TB cases in routine.

Cite

CITATION STYLE

APA

N’guessan, K., Adegbele, J., Coulibaly, I., Kouame-N’takpé, N., Seck-Angu, H., Guei, A., … Dosso, M. (2017). Clinical Performances of Pure TB-Lamp Kit for M. tuberculosis Complex Detection in Sputum Samples. Journal of Tuberculosis Research, 05(02), 129–138. https://doi.org/10.4236/jtr.2017.52014

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free