Abstract
The reproducibility of pulmonary function tests in the laboratory and in a mobile field survey vehicle has been studied. Groups of laboratory workers were studied at base and a random sample of 38 coalminers was examined in the mobile laboratory. The intra-subject variability of some newer tests of lung function, including closing volume and maximum flow at low lung volumes, has been compared with that of well-established tests, such as lung volumes and forced expiratory volume from 2 measurements made more than 1 day apart. Most measurements were slightly less reproducible in the study of coalminers than in the laboratory personnel. Conventional tests, such as forced expiratory volume in 1 sec, lung volumes, single breath CO transfer factor, and exercise ventilation were very reproducible, the coefficients of variation (cov) being generally between 5% and 10%. The closing volume test, maximum expiratory flow at low lung volumes, and the single breath N2 index were less reproducible: cov between 15% and 39% in the miners. The forced expired time and volume of isoflow, measured only on laboratory workers, however, exhibited greater reproducibility than previously reported (cov = 10% and 15% respectively). It is suggested that, when assessing the repeatability of lung function tests, account should be taken of the circumstances in which the intra-subject variability was measured.
Cite
CITATION STYLE
Love, R. G., Attfield, M. D., & Isles, K. D. (1980). Reproducibility of pulmonary function tests under laboratory and field conditions. British Journal of Industrial Medicine, 37(1), 63–69. https://doi.org/10.1136/oem.37.1.63