Experimental Studies on Thermal Performance of a Pulsating Heat Pipe with Methanol/DI Water

  • Verma B
  • Yadav V
  • Srivastava K
N/ACitations
Citations of this article
27Readers
Mendeley users who have this article in their library.

Abstract

The effect of working fluid on the start-up and thermal performance in terms of thermal resistance and heat transfer coefficient of a pulsating heat pipe have been studied in the present paper. Methanol and de-ionized water has been selected as the working fluid. The minimum startup power for DI water was obtained at 50% filling ratio and for methanol at 40%. The optimum filling ratio in terms of minimum startup power and minimum thermal resistance was 50% for DI water and 40% for methanol. The minimum thermal resistances for DI water and methanol were observed at vertical orientation. The evaporator side heat transfer coefficient for water was slightly more, while the condenser side heat transfer coefficient was appreciably more than that of methanol. Studies were also conducted for start-up time and temperature at different orientations and it was found that the PHP charged with methanol worked efficiently at all orientations.

Cite

CITATION STYLE

APA

Verma, B., Yadav, V. L., & Srivastava, K. K. (2013). Experimental Studies on Thermal Performance of a Pulsating Heat Pipe with Methanol/DI Water. Journal of Electronics Cooling and Thermal Control, 03(01), 27–34. https://doi.org/10.4236/jectc.2013.31004

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free